Understanding these new ladder regulations can be confusing and you can spend a great deal of time referencing the standard interpretations pages on the osha website and still not find the answers you need.
Osha fixed roof ladder.
Figure d 3 example of counterbalanced hatch cover at roof.
Section 1910 28 establishes the employer s duty to provide fall protection for employees on fixed ladders and 1910 29 specifies the criteria for fall protection systems for fixed ladders.
1917 118 e 2 i.
Note to paragraph d.
As of november 19 2018 the u s.
Per osha 1910 23 b 4 ladder rungs steps and cleats have a minimum clear width of 16 inches measured before installation of ladder safety systems for fixed ladders.
D 2 of this section with minimum clearances for intermediate pitches varying between these two limits in proportion to the slope except as provided in subparagraphs 3 and 5 of this paragraph.
On fixed ladders the perpendicular distance from the centerline of the rungs to the nearest permanent object on the climbing side of the ladder shall be 36 inches for a pitch of 76 degrees and 30 inches for a pitch of 90 degrees fig.
Fixed ladders more than 20 feet 6 1 m in height shall be provided with a cage well or ladder safety device.
1917 118 e 2 when a well or cage is used ladders with length of climb exceeding 30 feet 9 14 m shall comply with the following provisions.
Figure d 2 slide step fixed ladder sections.